1. Dripping from Nozzle 

2-2-1-1 - Verify if the duckbill valve is completely closed when idle.

  • Result 1 - The duckbill valve is not completely closed. 
    Start 2-2-1-2.


  • Result 2 - The duckbill valve is completely closed
    Start 2-2-1-3.

2-2-1-2 - Replace the duckbill valve, fill tube and make a test drink to verify the quality

  • Result - Drinks should be fine, but need to observe for a few days to check the dripping issue is not occurred again. 
    Issue closed. (Root cause: Duckbill valve failure)


2-2-1-3 - Fill tube and verify if the tube is empty for a bit while at the beginning.

  • Result 1 - The tube is empty for a bit while at the beginning. 
    Educate the customer to fill tube after the machine is idled overnight.
    Issue closed. (Root cause: Overnight ingredient dripping)

  • Result 2 - The ingredient can be dispensed smoothly all the time
    Start 2-2-2-1.




 2. Flowmeter  


2-2-2-1 - Replace the flowmeter (see fridge flowmeter SOP / ambient flowmeter SOP here) , and verify flowmeter functionality.


  • Result 1 - The flowmeter reading is accurate. 
    Start 2-2-2-2.


  • Result 2 - The flowmeter reading is inaccurate
    Escalate to FAE.



2-2-2-2 - Fill tube, and make a drink to verify the dispense wrong volume issue is resolved.


  • Result 1 - The drink can be made with the right volume and taste. 
    Issue close.

    Root cause: The flowmeter fails.
  • Result 2 - The dispense volume is still wrong
    Escalate to FAE.




Return to index